The consumer isn't allowed to open up the handles and panel of your procedure, neither Take note: machine disassemble is permitted. To ensure the method performance and protection, only Mindray engineers or engineers approved by Mindray can carry out routine maintenance.

The DP-fifty Qualified is surely an impressive, significant-general performance Ultrasound System engineered that can assist you receive the insights you may need. The System’s impressive motor and substantial-velocity processing give fantastic image high-quality and a complete facts management Option.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Be aware: Be sure that you can pull out and push into your IO board sockets vertically when pulling out and assembling the IO board assembly to the placement in the deal with. Take away panhead screws with washers M3X6 (4) accustomed to protected the IO board, after which you can you could potentially acquire out the IO board. Webpage 116 Eliminate panhead screws with washers (two M3X6) which might be mounted on the leading unit, take out the higher baffle after which pull out two cables connecting the most crucial board to the power module assembly.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

3. Click the upper icon inside the screen (prompts “Update” if you set the cursor on it), the update phase is carried out, if fails, make sure you send to R&D center. Figure six-one Key Watch Upkeep Display screen four. Soon after update is profitable, restart the machine immediately after energy off to make the information effective. HDD Partition ... Web site 91 structured report similar facts file and DICOM viewing application Report report template obd.bin OBD knowledge file Model.txt Version file Remark Remark file AnatomyImage Anatomical photos Measurement Measurement library Doppler method and associated boot configuration major file and plug-ins, remote desktop server Multilanguage string file exe videoplay.

General performance Examination five.five.one Check Course of action Resolution Detection depth Geometric Position Accuracy Blackout location take a look at History the Test photos 5.5.two Exam Material The picture applied here is only for reference, follow the picture result in the real Be aware: scenario. Needs: Screen: set the distinction and brightness for the medical application value (or maybe the default standing) Procedure ecosystem: dim area, simulating the clinical software surroundings. Webpage seventy six In problem which the transverse resolution screening targets are horizontally exhibited, report the nominal length of two targets that could be Obviously regarded. Repeat the operation higher than to the transverse resolution tests targets at other depths. As proven in determine below. Axial resolution ... Web site 77 When using the convex probe, retain the transverse resolution testing targets to NOTE: be shown close to the midline. When using a linear probe with steer purpose, don't turn on the steer functionality when carry out the transverse resolution check. Zoom in the region where by the targets Positioned if required. The diameter in the focus on place at a specific depth is equivalent into the transverse resolution in the depth. Webpage 78 five.

five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Exam Action: Do adjustments as the way in tests the utmost depth. History the gap by 20mm Every single segment on the longitudinal targets line using the measurement caliper; Choose the worth with the best error (to 20mm), work out the accuracy using the formula underneath The measurement caliper needs to be positioned at the upper fringe of the target, Observe:... Web page 79 Transverse geometric positioning precision  Test Phase: Cover the scan surface area of the phantom with water or few gel, gently contact the probe Along with the scan surface Alter the depth, earning the transverse targets for being shown during the picture. Alter the main focus place to be posited beside the transverse targets (the normal is just not apparent) Adjust parameters like acquire, TGC, earning Every transverse targets to become clearly displayed. Web page eighty 5.5.two.four Blackout Area Exam Move: Include the scan surface of your phantom with drinking water or couple gel, Carefully Speak to the probe Dp50rb login Along with the scan area Regulate the depth at a lower price, and set the main focus at the closest location to the scan surface. Lessen the value of parameters like AP, Get right up until the background sound just may be found. Website page eighty one: Application Upgrade And Upkeep

Observe: Right before uploading the log, make sure the ultrasound procedure has long been linked to network, if not, the process may well warn “couldn't connect to server” The server (smtp.

Our DP-50 Rated units can face up to hurricane-force winds approximately 173 mph. Devoted to delivering learn Wooden entry doorways to states with even the strictest developing necessities, DP-fifty Rated Models are DSA’s minimum Coastal Door Rating which meets or exceeds most non-affect setting up specifications alongside the east coast.

If you halt the scanning as well as graphic capture, you must electricity off the method and disconnect the method in the AC power source, then pull out AC electric power cables. Website page 109: Battery Connecting Board

Get a whole and extended see from the anatomical structure via panoramic imaging coupled with velocity indication and ahead/backward scan means earning scanning much easier, smoother and much more controllable.

Lower off cable ties connecting the primary unit within the Display screen by diagonal cutting pliers, after which you can pull out the corresponding cable plugs.

Your Software for further biopsy: permitting adjustments for the scan line to realize improved visibility from the needle, nerves and modest vessels, guaranteeing the continuity of all facts.